FEATURES

SITE PLAN

BUILDING SPECIFICATIONS

BUILDING SIZE

1,058,483 SF

CAR PARKING

831

TRAILER PARKING

360

DRIVE IN DOORS

(4) 12’ x 14’ – ELECTRICALLY OPERATED DOORS

COLUMN SPACING

50’ X 56’; 60’ X 56’ SPEED BAYS

CLEAR HEIGHT

40’

DOCK DOORS

(104) DOCK DOORS FULLY EQUIPPED WITH 45,000 LB MECHANICAL PIT LEVELERS; 7’ X 8’ PLATFORM; 16’ LIP; TOE GUARDS; NIGHT LOCKS; BRUSH WEATHER SEALS AND BUMPERS. EXPANDABLE TO 176 TOTAL DOCK DOORS.

FLOOR SLAB

7" NON-REINFORCED CONCRETE, 4,000 PSI

TRUCK COURT

130’ (185’ WITH TRAILER PARKING)

LIGHTING

LED WITH MOTION SENSORS, 30 FC AVERAGE; MEASURED AT 30” AFF

CONSTRUCTION

100% TILT UP CONCRETE

ELECTRICAL SERVICE

(2) 3,000 AMP SERVICES, 480 v 3 phase

SPRINKLER SYSTEM

ESFR

HVAC

CAMBRIDGE, ROOF-MOUNTED UNITS DESIGNED FOR 50℉ AT -0℉, 0.25 ACH

TAX INCENTIVES

10-YEAR LERTA TAX ABATEMENT

BUILDING SIZE

1,058,483 SF

CAR PARKING

831

TRAILER PARKING

360

DRIVE IN DOORS

(4) 12’ x 14’ – ELECTRICALLY OPERATED DOORS

COLUMN SPACING

50’ X 56’; 60’ X 56’ SPEED BAYS

CLEAR HEIGHT

40’

DOCK DOORS

(104) DOCK DOORS FULLY EQUIPPED WITH 45,000 LB MECHANICAL PIT LEVELERS; 7’ X 8’ PLATFORM; 16’ LIP; TOE GUARDS; NIGHT LOCKS; BRUSH WEATHER SEALS AND BUMPERS. EXPANDABLE TO 176 TOTAL DOCK DOORS.

FLOOR SLAB

7" NON-REINFORCED CONCRETE, 4,000 PSI

TRUCK COURT

130’ (185’ WITH TRAILER PARKING)

LIGHTING

LED WITH MOTION SENSORS, 30 FC AVERAGE; MEASURED AT 30” AFF

CONSTRUCTION

100% TILT UP CONCRETE

ELECTRICAL SERVICE

(2) 3,000 AMP SERVICES, 480 v 3 phase

SPRINKLER SYSTEM

ESFR

HVAC

CAMBRIDGE, ROOF-MOUNTED UNITS DESIGNED FOR 50℉ AT -0℉, 0.25 ACH

TAX INCENTIVES

10-YEAR LERTA TAX ABATEMENT