SITE PLAN

BUILDING SPECIFICATIONS
BUILDING SIZE
1,058,483 SF
CAR PARKING
831
TRAILER PARKING
360
DRIVE IN DOORS
(4) 12’ x 14’ – ELECTRICALLY OPERATED DOORS
COLUMN SPACING
50’ X 56’; 60’ X 56’ SPEED BAYS
CLEAR HEIGHT
40’
DOCK DOORS
(104) DOCK DOORS FULLY EQUIPPED WITH 45,000 LB MECHANICAL PIT LEVELERS; 7’ X 8’ PLATFORM; 16’ LIP; TOE GUARDS; NIGHT LOCKS; BRUSH WEATHER SEALS AND BUMPERS. EXPANDABLE TO 176 TOTAL DOCK DOORS.
FLOOR SLAB
7" NON-REINFORCED CONCRETE, 4,000 PSI
TRUCK COURT
130’ (185’ WITH TRAILER PARKING)
LIGHTING
LED WITH MOTION SENSORS, 30 FC AVERAGE; MEASURED AT 30” AFF
CONSTRUCTION
100% TILT UP CONCRETE
ELECTRICAL SERVICE
(2) 3,000 AMP SERVICES, 480 v 3 phase
SPRINKLER SYSTEM
ESFR
HVAC
CAMBRIDGE, ROOF-MOUNTED UNITS DESIGNED FOR 50℉ AT -0℉, 0.25 ACH
TAX INCENTIVES
10-YEAR LERTA TAX ABATEMENT
BUILDING SIZE
1,058,483 SF
CAR PARKING
831
TRAILER PARKING
360
DRIVE IN DOORS
(4) 12’ x 14’ – ELECTRICALLY OPERATED DOORS
COLUMN SPACING
50’ X 56’; 60’ X 56’ SPEED BAYS
CLEAR HEIGHT
40’
DOCK DOORS
(104) DOCK DOORS FULLY EQUIPPED WITH 45,000 LB MECHANICAL PIT LEVELERS; 7’ X 8’ PLATFORM; 16’ LIP; TOE GUARDS; NIGHT LOCKS; BRUSH WEATHER SEALS AND BUMPERS. EXPANDABLE TO 176 TOTAL DOCK DOORS.
FLOOR SLAB
7" NON-REINFORCED CONCRETE, 4,000 PSI
TRUCK COURT
130’ (185’ WITH TRAILER PARKING)
LIGHTING
LED WITH MOTION SENSORS, 30 FC AVERAGE; MEASURED AT 30” AFF
CONSTRUCTION
100% TILT UP CONCRETE
ELECTRICAL SERVICE
(2) 3,000 AMP SERVICES, 480 v 3 phase
SPRINKLER SYSTEM
ESFR
HVAC
CAMBRIDGE, ROOF-MOUNTED UNITS DESIGNED FOR 50℉ AT -0℉, 0.25 ACH
TAX INCENTIVES
10-YEAR LERTA TAX ABATEMENT